Proline Promag 50H, 53H
Endress+Hauser 7
FOUNDATION Fieldbus interface
FOUNDATION Fieldbus H1
Transmission technology (Physical Layer): IEC 61158-2 (MBP), galvanically isolated
•ITK version 5.01
Current consumption: 12 mA
Error current FDE (Fault Disconnection Electronic): 0 mA
Bus connection with integrated reverse polarity protection
•Function blocks:
5 × Analog Input (execution time: 18 ms each)
1 × PID (25 ms)
1 × Digital Output (18 ms)
1 × Signal Characterizer (20 ms)
1 × Input Selector (20 ms)
1 × Arithmetic (20 ms)
–1 × Integrator (18 ms)
Output data: volume flow, calculated mass flow, totalizer 1 to 3
Input data: positive zero return (ON/OFF), reset totalizer
Link Master (LM) functionality is supported
Signal on alarm Current output failure response selectable (e.g. in accordance with NAMUR recommendation NE
43)
Pulse/frequency output failure response selectable
Status output (Promag 50) "non-conductive" by fault or power supply failure
Relay output (Promag 53) "de-energized" by fault or power supply failure
Load See "Output signal"
Low flow cutoff Switch points for low flow cutoff are selectable.
Galvanic isolation All circuits for inputs, outputs and power supply are galvanically isolated from each other.
Switching output Status output (Promag 50, Promag 53)
Open collector, max. 30 V DC / 250 mA, galvanically isolated.
Configurable for: error messages, Empty Pipe Detection (EPD), flow direction, limit values
Relay outputs (Promag 53)
Normally closed (NC or break) or normally open (NO or make) contacts available
(factory setting: relay 1 = NO, relay 2 = NC),
max. 30 V / 0.5 A AC; 60 V / 0.1 A DC, galvanically isolated.
Configurable for: error messages, Empty Pipe Detection (EPD), flow direction, limit values, batching
contacts