Proline Promag 50H, 53H
46 Endress+Hauser
Process connections orderable only as accessories with aseptic gasket seal, DN 15
Ground rings (accessories for PVDF flanges / PVC adhesive fitting), DN 2 to 25 / ¹⁄₁₂ to 1"
Tri-Clamp for L14 AM7
1.4404 (316L)
Sensor DN Fits to piping di G L H × B
DKH**-HF** [mm] OD [mm] [mm] [mm] [mm]
A0005555
15 Tube 25.4 × 1.65
(ODT 1")
22.1 50.4 28.5 62 × 42
• Fitting length = (2 × L) + 86 mm
• Surface roughness: R
a
0.8 m
• If pigs are used for cleaning, it is essential to take the inside diameters
of measuring tube and process connection (di) into account!
For lap joint flange made of PVDF
and PVC adhesive sleeve
1.4435 (316L)
Alloy C22 tantalum
Sensor DN di B C D
DK5HR – **** [mm] [mm] [mm] [mm] [mm]
A0005568
2 to 8 9.0 22.0 17.6 33.9
15 16.0 29.0 24.6 33.9
25 (1" ANSI) 22.6 36.5 31.2 43.9
25 (DIN) 26.0 39.0 34.6 43.9