Proline Promag W 400
32 Endress+Hauser
Electromagnetic
compatibility (EMC)
• As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
• Complies with emission limits for industry as per EN 55011 (Class A)
Details are provided in the Declaration of Conformity.
Process
Medium temperature range
• 0 to +80 °C (+32 to +176 °F) for hard rubber, DN 50 to 2000 (2 to 78")
• –20 to +50 °C (–4 to +122 °F) for polyurethane, DN 25 to 1200 (1 to 48")
Conductivity
≥ 5 μS/cm for liquids in general
Note that in the case of the remote version, the requisite minimum conductivity also depends
on the cable length (→ 29).
Pressure-temperature
ratings
The following material load diagrams refer to the entire device and not just the process connection.
Flange connection according to EN 1092-1 (DIN 2501)
0
5
10
15
20
25
35
30
40
[bar][psi]
-40
-20
0 20
40 60 80 100120140160180 [°C]
360 [°F]
0-40 100 200 300
200
100
400
300
500
600
0
PN25
PN16
PN10
PN 6
PN40
A0021188-EN
19 Fixed flange PN 6/10/16/25/40, materials C22, FE 410W B and S235JRG2, DN 25 to 2000 (1 to 78")