Proline Promag W 400
Endress+Hauser 17
Supply voltage Transmitter
Order code for "Power supply" Terminal voltage Frequency range
Option L
AC100 to 240 V 50/ 60 Hz, ±4 Hz
AC/DC24 V 50/ 60 Hz, ±4 Hz
Power consumption
Order code for
"Output"
Maximum
Power consumption
Option L 30 VA/8 W
Option N 30 VA/8 W
Current consumption Transmitter
Order code for "Power supply" Maximum
Current consumption
Maximum
switch-on current
Option L: AC 100 to 240 V 145 mA 25 A (< 5 ms)
Option L: AC/DC 24 V 350 mA 27 A (< 5 ms)
Power supply failure
Totalizers stop at the last value measured.
Configuration is retained in the plug-in memory (HistoROM DAT).
Error messages (incl. total operated hours) are stored.
Electrical connection Connecting the transmitter
A B
1 2
2221
A0017113
 2 Supply voltage and signal transmission connection
A Compact version
B Remote version wall-mount housing
1 Cable entry for supply voltage
2 Cable entry for signal transmission
Remote version connection
Connecting cable
A0017267
 3 Connecting cable connection: electrode and coil current cable
A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable

Table of Contents