Proline Promag W 800
Endress+Hauser 21
Installation in partially filled pipes with a gradient
Partially filled pipes with gradients necessitate a drain-type configuration.
Risk of solids accumulating.
• Do not install the sensor at the lowest point in the drain.
• It is advisable to install a cleaning valve.
A0017063
Installation in a partially filled pipe
For very heavy sensors
If the nominal diameter DN 350 (14"), mount the sensor on a foundation of adequate load-bearing strength.
Do not support the weight of the sensor on the metal casing as this could damage the metal casing and
the internal magnetic coils.
A0016276
Correct support for large nominal diameters DN 350 (14")