Proline Promag W 800
26 Endress+Hauser
Vibration resistance Acceleration up to 2 g following IEC 600 68-2-6
Mechanical load Transmitter housing
The transmitter housing must be protected against mechanical effects, such as shock, impact etc.
It is sometimes preferable to use the remote device version.
The transmitter housing must never be used as a ladder or climbing aid!
Electromagnetic
compatibility (EMC)
In accordance with IEC/EN 61326
GSM/GPRS signal strength It is important to ensure that the signal of the mobile communications network is strong enough to enable the
system to dial into the GPRS/GSM network.
Process
Medium temperature range Sensor
The permissible temperature depends on the lining of the measuring tube.
–20 to +50 °C (–4 to +122 °F) for polyurethane, DN 25 to 600 (1 to 24")
0 to +80 °C (+32 to +176 °F) for hard rubber, DN 50 to 600 (2 to 24")
Conductivity The minimum conductivity is 50 μS/cm.
Pressure-temperature ratings The following material load diagrams refer to the entire device and not just the process connection.
Flange connection according to EN 1092-1 (DIN 2501)
A0005594
PN 6/10/16/25/40, materials C22, FE 410W B and S235JRG2, DN 25 to 600 (1 to 24")
PN 25
PN 16
PN 10
PN 6
PN 40
0
5
10
15
20
25
35
30
40
[bar][psi]
-60
-40
-20
020
40 60 80 100 120 140 160 180 [°C]
360 [°F]
0-40 100 200 300
200
100
400
300
500
600
0

Table of Contents