Proline Promag W 800
Endress+Hauser 9
This is also the case if the measuring device uses an external power supply.
Configuration 1
Configuration 2
Configuration 3
Configuration 4
Configuration 5
Configuration of batteries Connectors
Number of
batteries
Battery usage
A0017127
B 1 1 Backup power supply for the measuring device
B 2 1 Power supply for the measuring device
B 3 – Power supply for the GSM/GPRS modem
"Power supply" order feature for this configuration: 5W8B**–***F0********
!
Note!
Not permitted in custody transfer!
Configuration of batteries Connectors
Number of
batteries
Battery usage
A0017128
B 1 1 Backup power supply for the measuring device
B 2 3 Power supply for the measuring device
B 3 – Power supply for the GSM/GPRS modem
"Power supply" order feature for this configuration: 5W8B**–***G0********
Configuration of batteries Connectors
Number of
batteries
Battery usage
A0017129
B 1 3 Backup power supply for the measuring device
B 2 3 Power supply for the measuring device
B 3 – Power supply for the GSM/GPRS modem
"Power supply" order feature for this configuration: 5W8B**–***H0********
Configuration of batteries Connectors
Number of
batteries
Battery usage
A0017130
B 1 1 Backup power supply for the measuring device
B 2 – Power supply for the measuring device
B 3 – Power supply for the GSM/GPRS modem
Powered via external power
supply
Power supply for the measuring device
"Power supply" order feature for this configuration: 5W8B**–***J0********
Configuration of batteries Connectors
Number of
batteries
Battery usage
A0017131
B 1 1 Backup power supply for the measuring device
B 2 2 Power supply for the measuring device
B 3 3 Power supply for the GSM/GPRS modem
"Power supply" order feature for this configuration: 5W8B**–***HP********