Proline Promass I 100 Modbus RS485 Technical data
Endress+Hauser 89
Materials Transmitter housing
• Order code for "Housing", option A "Compact, coated alu":
Coated aluminum AlSi10Mg
• Order code for "Housing", option B "Compact, hygienic, stainless":
Hygienic version, stainless steel 1.4301 (304)
• Order code for "Housing", option C "Ultra compact hygienic, stainless":
Hygienic version, stainless steel 1.4301 (304)
Cable entries
Order code for "Housing", option A "Compact, coated alu"
The various cable entries are suitable for hazardous and non-hazardous areas.
Electrical connection Material
Cable gland M20 × 1.5 Nickel-plated brass
Thread G ½", via adapter
Thread NPT ½", via adapter
Order code for "Housing", option B "Compact, hygienic, stainless"
The various cable entries are suitable for hazardous and non-hazardous areas.
Electrical connection Material
Cable gland M20 × 1.5 Stainless steel 1.4404 (316L)
Thread G ½", via adapter
Thread NPT ½", via adapter
Device plug
Electrical connection Material
Plug M12x1 • Socket: Stainless steel 1.4404 (316L)
• Contact housing: Polyamide
• Contacts: Gold-plated brass
Sensor housing
• Acid and alkali-resistant outer surface
• Stainless steel 1.4301 (304)
Measuring tubes
Grade 9 titanium
Surface quality:
• Not polished
• Ra
max
= 0.8 µm (32 µin)
• Ra
max
= 0.4 µm (16 µin)