57
© 2017 Energreen Srl
Professional machinery
Error Cause Measures
70 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
71 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
72 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
73 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
74 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
75 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
76 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
77 Radio control lever value incorrect
Check the remote control, check the control unit parameters. If
the error persists, replace the remote control.
80 CAN message reception error from the machine display
Check the display, check the CAN line, check the LE70. If the
error persists, replace the display.
81 Machine display system error If the error persists, replace the display.
90 Machine inclinometer system error If the error persists, replace the inclinometer.
91 CAN message reception error from inclinometer
Check the inclinometer, check the CAN line, check the LE70, if
the error persists, replace the inclinometer.
200 Engine protection alarm See SPN and FMI codes to understand the reason for the alarm
201 Engine warning alarm See SPN and FMI codes to understand the reason for the alarm
202 Stop engine alarm See SPN and FMI codes to understand the reason for the alarm
203 Engine fault alarm See SPN and FMI codes to understand the reason for the alarm
204 Engine alarm
Battery voltage: the voltage measured by the ECU is outside the
target range.
205 Engine alarm
Battery voltage: the voltage measured by the ECU is outside the
target range; the ECU activates a system response
206 Engine alarm
Coolant level: the level of coolant calculated by the ECU is less
than the minimum permitted amount
207 Engine alarm
Air heater relay indicator: the energy consumption measured
by the ECU does not fall within the permissible range or the
maximum permissible temperature of the ECU component that
powers the lamp has been exceeded
208 Engine alarm
Coolant temperature sensor: the sensor voltage measured by
the control unit does not fall within the permissible range; the
temperature of the coolant calculated by the control unit is ques-
tionable when compared to the oil temperature, or the value
received via the CAN is incorrect
209 Engine alarm
Coolant temperature: the temperature of the coolant calculated
by the control unit is higher than the permissible range; the ECU
activates a system response
210 Engine alarm
Oil level indicator: the energy consumption measured by the
ECU does not fall within the permissible range or the maximum
permissible temperature of the ECU component that powers the
lamp has been exceeded
211 Motor CAN message reception error
Check the engine, check the CAN line, check the LE70. If the
error persists, check the engine control unit.
500 Problems with output pin A24 of control unit LE70 Check the wiring. Controller output error
501 Problems with output pin A13 of control unit LE70 Check the wiring. Controller output error
502 Problems with output pin A01 of control unit LE70 Check the wiring. Controller output error
503 Problems with output pin A02 of control unit LE70 Check the wiring. Controller output error
504 Problems with output pin A03 of control unit LE70 Check the wiring. Controller output error
505 Problems with output pin A04 of control unit LE70 Check the wiring. Controller output error
506 Problems with output pin A05 of control unit LE70 Check the wiring. Controller output error
507 Problems with output pin A06 of control unit LE70 Check the wiring. Controller output error
508 Problems with output pin A07 of control unit LE70 Check the wiring. Controller output error
If the fault or the reason for it is not indicated in the list of faults shown, contact ENERGREEN in order for repairs to be carried out.