9.9 - CHECKING AND MAINTAINING THE ELECTRICAL SYSTEM
This is a visual inspection that must be carried out with the utmost care in order to avoid short-
circuits in the system that would damage the machine.
Specically check every 250 hours
Fuses, if corroded or rusty, replace them with fuses of the same capacity.
Batteries (B), check the battery clamp connections. If they are oxidised, remove the oxidation
and coat them with appropriate grease. When carrying out this operation, be very careful not
to let the earth wire (black) touch the power supply wire (red).
Starter motor, check the cables.
Alternator, check the cables.
Check the tightness of connectors
If the cables show signs of a short circuit, look for the causes and contact the
ENERGREEN customer care department.
WARNING:
Electrical system maintenance tasks are:
Checking the tension of the timing belt (A).
Checking the battery charge (B).
Furthermore, make sure that:
No modications are made to the electrical system without ENERGREEN's authorisation.
Do not remove or install any components without the prior authorisation of ENERGREEN.
Prevent the electrical system from coming into contact with water.
Protect the connection pins with anti corrosives.
Checking and maintaining the electrical system