9.6.3 - CHECK AND REPLACEMENT OF THE HYDRAULIC OIL FILTER
The hydraulic oil lter should be replaced every 1000
hours or when the clogging warning indicator (A)
on the LCD display comes on (section 6.9.1).
• Unscrew the red cap (B) above the lter.
• Extract the ltering element (C);
• Filters should only be replaced with original lters
and before they become completely clogged.
• Check always the O-ring status when a
component of the hydraulic circuit is dismounted
or is replaced. If broken or damaged, replace
them.
• Close the cap again and tighten it with the
spanner with a maximum torque of 20 Nm.
B
A
C