9.6.3 - CHECK AND REPLACEMENT OF THE HYDRAULIC OIL FILTER
The hydraulic oil lter should be replaced every 1000
hours or when the clogging warning indicator (A)
on the LCD display comes on (section 6.9.1).
Unscrew the red cap (B) above the lter.
Extract the ltering element (C);
Filters should only be replaced with original lters
and before they become completely clogged.
Check always the O-ring status when a
component of the hydraulic circuit is dismounted
or is replaced. If broken or damaged, replace
them.
Close the cap again and tighten it with the
spanner with a maximum torque of 20 Nm.
B
A
C