9.5.4 - COOLANT LEVEL CHANGE
DANGER:
The violent expulsion of coolant under pressure can cause serious burns.
Turn off the engine.
Remove the fuel ller cap only when it has cooled down enough to be touched
with the bare hand. Before removing the cap, slowly loosen it until the rst stop to
relieve the pressure.
Coolant
Changing frequency
Hours Years
Total Glacelf Auto Supra 2000 2
Other coolants 2000 2
Changing the coolant
To replace the coolant, follow the steps below:
Position the machine on a at surface and switch
off the engine.
Loosen the radiator cap (A) slowly in order to
discharge any residual pressure.
A
Unscrew the two screws (C) at the sides and lift the
radiator grille guard (B).
Fasten the guard in position using the pin (D).
D
B
C