77
© 2017 Energreen Srl
Professional machinery
Changing the coolant
Release the three tie rods (F) and open the radiator
grille (E).
E
F
Remove the four screws and then remove the
bottom casing (G).
G
Unscrew the drainage plug (H) and collect the liquid
in a specic container.
Once all the liquid has been removed, tighten the
drainage plug (H).
Fill the radiator via the ller cap (A) until the ns
of the radiator are covered, making sure that no
bubbles form during lling.
Close the radiator cap (A).
Fill the reserve tank via the cap (I) up to the level
indicated by the reference marks. Close the cap (I).
Start the engine and leave it running until it reaches
normal working temperature.
Recheck the level of uid in the reserve tank and
top it up if the level of liquid is below than the
minimum mark.
Quantity required for lling: 15 litres
H
MIN
MAX
I