77
© 2017 Energreen Srl
Professional machinery
Changing the coolant
• Release the three tie rods (F) and open the radiator
grille (E).
E
F
• Remove the four screws and then remove the
bottom casing (G).
G
• Unscrew the drainage plug (H) and collect the liquid
in a specic container.
• Once all the liquid has been removed, tighten the
drainage plug (H).
• Fill the radiator via the ller cap (A) until the ns
of the radiator are covered, making sure that no
bubbles form during lling.
• Close the radiator cap (A).
• Fill the reserve tank via the cap (I) up to the level
indicated by the reference marks. Close the cap (I).
• Start the engine and leave it running until it reaches
normal working temperature.
• Recheck the level of uid in the reserve tank and
top it up if the level of liquid is below than the
minimum mark.
Quantity required for lling: 15 litres
H
MIN
MAX
I