1 - 144
Chapter 1 Troubleshooting
Epson AcuLaser C2900N
Revision B
Confidential
6
Checking the DRUM CARTRIDGE for connection.
Remove the DRUM CARTRIDGE.
Are five HV terminals on the DRUM CARTRIDGE, and five
springs on the frame (PL4.1.10 and PL4.1.15 to 18) dirty
and/or deformed?
Clean and/or
replace the DRUM
CARTRIDGE or
SPRING(s).
Go to step 7.
7
Checking after replacing the DRUM CARTRIDGE.
Replace the DRUM CARTRIDGE. (Refer to RRP4.6.)
Is the image printed correctly?
End of work.
Warning: Start the
operation after the
fuser unit has
cooled down.
Replace the fuser
unit. (Refer to
RRP6.1.) After
replacement, be
sure to clear the
life counter value.
Step Check
Remedy
Yes No

Table of Contents