2 - 46
Chapter 2 Operation of Diagnostic
Epson AcuLaser C2900N
Revision B
Confidential
4.6.2 Executing Parameter (Life Counter)
1) Turn off the power.
2) Turn on the power while holding down "S" and "T" keys.
3) Release the fingers from these keys when the "CE Mode" and "Password" is displayed.
4) Press "T" key twice and press "OK" key.
5) The "CE Mode" and "ESS Diag" are displayed. (Entered the Diag. mode.)
6) Press "T" to select "Parameter", and then press "OK" key.
7) Press "S" and "T" key to select the Life Counter item, and then press "OK" key .
8) Press "OK" key to execute the setting.
The current life counter value is displayed.
To exit the test or to returning to one step higher menu, press "STOP" key.
- Reference Counter Values
These counter values are reference only. Do not use as the official value.
Counter Name Value of life warning
Life Y Toner Std.:1000/High:2500
Life M Toner Std.:1000/High:2500
Life C Toner Std.:1000/High:2500
Life K Toner Std.:1000/High:3000
Life Fuser Unit 50000
Life Printer 100000
Life DTB (Transfer Belt) -
Life Y Waste Toner -
Life M Waste Toner -
Life C Waste Toner -
Life K Waste Toner -
Life Y Drum 24000
Life M Drum 24000
Life C Drum 24000
Life K Drum 24000
Life Drum Xero -
Life Drum Deve K -
Life SSI Sheet -
Life Tray 1 Sheet -
Life Tray 2 Sheet -
Life Duplex Sheet -
Life Custom In -