EasyManua.ls Logo

Epson AcuLaser C2900N - Page 219

Epson AcuLaser C2900N
681 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 15
Chapter 2 Operation of Diagnostic
Epson AcuLaser C2900N
Revision B
Confidential
Regi Sensor
(DI-2)
NOTE: When performing operation for five minutes or longer with the
front cover open, remove the drum cartridge, and cover the drum to
avoid exposure to light.
1) Power on the printer, and enter the Diag Mode.
2) Open the Front Cover.
3) Execute DI-2.
4) Manually operate the actuator to check whether the sensor
functions properly.
5) Check that the number in the bottom line of the display
increases by one every time the actuator is operated.
6) Press the "STOP" key to stop the test.
7) Close the Front Cover.
Exit Sensor
(DI-3)
NOTE: Because the fuser unit is very hot, be careful not to burn
yourself.
1) Power on the printer, and enter the Diag Mode.
2) Open the Front Cover.
3) Execute DI-3.
4) Manually operate the actuator to check whether the sensor
functions properly.
5) Check that the number in the bottom line of the display
increases by one every time the actuator is operated.
6) Press the "STOP" key to stop the test.
7) Close the Front Cover.
Sensor Name (Diag. Code) Check Procedure
Actuator
MiS02005SA
MiS02006GA

Table of Contents

Other manuals for Epson AcuLaser C2900N

Related product manuals