2 - 30
Chapter 2 Operation of Diagnostic
Epson AcuLaser C2900N
Revision B
Confidential
Tray2 Turn Clutch
(DO-33)
NOTE: This procedure is for the technical staff.
Combination test is as follows:
Tray 2 turn roll rotates when DO-17 and DO-33 are executed.
1) Remove the COVER CHUTE.
2) Power on the printer, and enter the Diag Mode.
3) Remove the Tray 1 and Tray 2.
4) Execute DO-17 and DO-33.
5) Check that the Turn Roll rotates.
6) Press the "STOP" key to stop the clutch.
7) Press the "T" key to display DO-17.
8) Press the "STOP" key to stop the motor.
9) Replace the COVER CHUTE, Tray 1 and Tray 2.
Motor/Clutch/Solenoid Name
(Diag. Code)
Check procedure