Chapter 3 Removal and Replacement Procedures Revision B
Epson AcuLaser C2900N 3 - 216 Confidential
9) Route the harness of the SWITCH
ASSY INLET MG SFP along the GUIDE
HARNESS AC, secure the grounding
terminal of the SWITCH ASSY INLET MG
SFP with the one screw (silver, with
washer, 6mm).
Engage the connector (P/J48) of the
SWITCH ASSY INLET MG SFP to the
PWBA
LVPS.
10) Route the harness along the GUIDE
HARNESS AC, engage the five connectors
(P/J20, 23, 24, 26 and 28) with the PWBA
MCU.