EasyManua.ls Logo

Epson Aculaser M2000 series - Environmental; Mechanical; Electrical; Standard and Approvals

Epson Aculaser M2000 series
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specifications 156
Environmental
*
The recommended environment is 15 to 28 °C (59 to 82 °F) and 20 to 70 % RH.
Mechanical
Electrical
*
Values represent power consumption while all operations are completely suspended. Power consumption varies
depending on errors and operating conditions.
Standard and approvals
European model:
Temperature: In use:
*
10 to 32.5 °C (50 to 90.5 °F)
Not in use: 0 to 35 °C (32 to 95 °F)
Humidity: In use:
*
15 to 80 % RH
Not in use: 5 to 85 % RH
Altitude: 2500 meters (8200 feet) maximum
Dimensions Height: 255 mm (10.0 in.)
Width: 378 mm (14.9 in.)
Depth: 390 mm (15.4 in.)
Weight Approx. 11.5 kg (about 25.4 lb)
(Excluding consumables and options)
Rated voltage 110 V - 120 V 220 V - 240 V
Rated frequency 50 Hz / 60 Hz 50 Hz / 60 Hz
Rated current 8.9 A 3.9 A
Power consumption During
printing
Average 449 W 465 W
MAX 780 W 840 W
During ready mode 7 W 7 W
During sleep mode
*
3 W 3 W

Table of Contents

Other manuals for Epson Aculaser M2000 series

Related product manuals