4.2.2  Removing the Housing
4.2.2.1  ADF Unit (Artisan 800/PX800FW/TX800FW only)
 Parts/Components need to be removed in advance:
None
 Removal procedure
1. Open the Scanner Unit.
2. Cut the harness cover clamp with a nipper as shown in Fig. 4-3 and remove 
the harness cover clamp. 
3. Slide the Cable Cover to the rear of the printer by pushing the point A of the 
Cable Cover to release the hooks (x4) and ribs (x2), and remove the Cable 
Cover.
Figure 4-3.  Removing the Cable Cover
4. Disconnect the ADF Motor Cable and ADF Sensor Cable from the connectors 
on the Main Board. (See 
Fig. 4-4.)
5. Pull out the terminal of the Grounding Wire from the fixing rib of the frame.
Figure 4-4.  Removing the ADF Unit (1)
The harness cover clamp needs to be cut when removing, and 
cannot be reused. When installing the Cable Cover, replace it with a 
new one. 
Figure 4-2.  Damaged stopper
Harness cover clamp before cut
Harness cover clamp after cut
Harness cover clamp
Cable Cover
Right side
Point A
Harness cover clamp
Cutting position
Grounding Wire
Terminal of Grounding 
Wire and the fixing rib
Main Board
ADF Motor Cable
ADF Sensor Cable