Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W Revision C
DISASSEMBLY/ASSEMBLY      Routing FFC/cables 203
Confidential
MAIN BOARD (TOP SIDE) (ARTISAN 800/PX800FW/TX800FW)
The following describes the routing orders of the cables and FFCs that are connected to 
the Main Board.
Figure 4-245.  Connector positions on the Main Board
(Artisan 800/PX800FW/TX800FW)
Figure 4-246.  Main Board (Artisan 800/PX800FW/TX800FW)
Start Cable Route CN No.
1
PE Sensor Cable 
(Ferrite Core x2)
a → groove → I → J → b CN9
PF Encoder FFC Double-sided tape (x4) CN8
2
PF Motor Cable 
(Ferrite Core x1)
H → c → F → E → B CN22
3
CR Motor Cable 
(Ferrite Core x1)
K → d → F → E → B CN21
4 Decompression Pump Motor Cable K → F → E → B CN24
5
Duplex Unit Sensor Cable
G → D → C
CN13
CDR Tray Sensor Cable CN14
Photo Tray Sensor Cable G → D → C → I → J CN12
6 Power Supply Unit Cable Align it to standard line → A CN501
CN501
CN22
CN21
CN24
CN49
CN25 CN14
CN13 CN8
CN41 CN10
CN51
CN12
CN9
CN6 CN4 CN3 CN2
CN1
CN36
CN5
CN19
CN31
CN7
CN32
I
J
Hook
Double-sided tape
Power Supply Unit Cable
PF Motor Cable
CR Motor Cable
Decompression 
Pump Motor Cable
Duplex Unit 
Sensor Cable
CDR Tray 
Sensor Cable
PF Encoder FFC
PE Sensor Cable
Photo Tray 
Sensor Cable
Base line
1
2
3
4
5
6
b
d
c
A K
a d
Ferrite Core position
Routing hole for the FFC/cable
1 6
Acetate tape
http://www.manuals4you.com