Setting Options Description
DC Out (2.0A)/GPI In Settings
(continued)
GPI-1 Settings
GPI-2 Settings
GPI Info.
GPI-1 Settings/GPI-2 Settings: set the
operation to be executed when the
sensor signal exceeds or falls below a
certain voltage. Select the Low -> High
setting to select the operation for when
the sensor signal exceeds a certain
voltage. Select the High -> Low setting
to select the operation for when the
sensor signal falls below a certain
voltage.
Favorite Playlists: set which playlist to
play when you have selected the Start
Playlist setting
Source: set the image source when
you have selected the Source Select
setting
Combination: set the settings for the
combination of GPI-1 and GPI-2
signals
Hold High/Hold Low: set how long the
High or Low signal is held before
executing the selected operation
GPI Info.: displays the current value for
GPI-1 and GPI-2