Epson Stylus Pro 4900/Epson Stylus Pro 4910 Revision A
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 179
Confidential
3.4.4.6 APG Motor Assy
1. Remove the Front Cover. (p142)
2. Remove the Right Upper Cover. (p138)
3. Remove the Control Panel Cover. (p136)
4. Remove the Right Cover. (p139)
5. Disconnect the connector from the APG Motor Assy.
6. Remove the four screws that secure the APG Motor Assy, and remove the APG
Motor Assy.
A) Silver, Phillips, Bind machine screw M3x6: four pieces
Figure 3-89. Removing the APG Motor Assy
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 4 “Adjustment” (see p277) and perform
specified adjustments after replacing or removing the APG Motor
Assy.
<Adjustment items>
1. Counter Reset (APG Motor Assy Counter)
(After replacement only)
2. APG Check
APG Motor Assy
Connector
A
A
A
A