Epson Stylus Pro 4900/Epson Stylus Pro 4910 Revision A
ADJUSTMENT Head Related Checks and Adjustments 344
Confidential
ADJUSTMENT PROCEDURE
1. Turn the printer power on.
2. Start the Service Program, and select [Colorimetric Calibration Tool].
3. Click [Run] to start the “Colorimetric Calibration Tool”.
4. Select the printer model.
5. Make sure that the “READY” message is displayed on the printer LCD, and click
[Next].
Figure 4-51. Colorimetric Calibration ID Startup Screen
C A U T I O N
When several drivers are installed for one printer, check that the
backlight of the LCD panel on the printer flashes by selecting the
printer model and click [Next].
C H E C K
P O I N T
If the printer has not been used for more than two weeks, it is
recommended to agitate the ink inside the cartridges to get an
accurate result. Remove all the ink cartridges from the printer, and
shake them gently for four or five times.