Epson Stylus Pro 4900/Epson Stylus Pro 4910 Revision A
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 271
Confidential
3.4.12.6 CR HP Sensor
1. Remove the Color Measurement Device. (p255)
2. Remove the Mounter. (p132)
3. Remove the Upper Cover. (p257)
4. Open the Front Cover, and move the carriage to the right.
(Step 6 in “3.4.12.5 Paper Pressing Motor” (P. 269))
5. Disengage the hooks that secure the CR HP Sensor, and remove the CR HP
Sensor.
6. Disconnect the connector from the CR HP Sensor.
Figure 3-214. Removing the CR HP Sensor
CR HP Sensor
Connector
Hooks

Table of Contents