WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C
Disassembly And Assembly Removing the Motors 120
Confidential
4.5 Removing the Motors
4.5.1 CR Motor
1. Remove the ASF Assy. (p.96)
2. Release the Carriage Lock, and move the Carriage Unit to the center.
(Refer to 4.1.5
Locking/Releasing the Carriage (p.65).)
3. Remove the two Clamps. (Refer to 4.4.13 Ink System Unit (p.107).)
4. Disconnect the CR Motor connector cable from the connector CN115 on the Main
Board.
5. Remove the CR Motor connector cable from the Cord Keep.
Figure 4-146. Removing the CR Motor connector cable
Attach two pieces of acetate tape (18 mm) on the Upper Shield
Plate.
Figure 4-147. Attaching acetate tape
Route the cables as shown below.
Figure 4-148. Routing the cables