EasyManua.ls Logo

Ericsson MD110 - Extension Equipment

Ericsson MD110
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADMINISTRATION AND EXAMPLE PROGRAMMING LBI-39039B
37
5.6.2. Extension Equipment
Extensions are initiated with the command EXTEI, and 4001 through 4008 are initialized.
EXTEI
DIR 4001&&4008
CAT 0
EQU
LIM 1
Magazine X X must be entered in the script file
Board Position XX XX must be entered in the script file
Board Circuit No. 0
TYPE EL6
TRM
Transmission Category 0 No attenuation or amplification
ICAT
Instrument Class 000 EL6 analog
Instrument type 0 Hookflash capable, normal intercept tone and
normal ringing
ADC
Bearer services 0 Speech and 3.1 kHz
CLI request 0 Not requested
CLI presentation 0 Allowed
Call metering 0 Not in US (Per route)
Malicious call trace 0 Not in US
Manual message waiting 0 Not allowed
Transfer outgoing calls 0 Not allowed to accept transferred or to transfer
outgoing external calls
Authorization code 0 Does not need to match extensions
Network affiliation 0 Common public number sent to network

Table of Contents

Other manuals for Ericsson MD110

Related product manuals