LIM CONFIGURATIONS FOR PRIVATE NETWORK CONNECTIONS LBI-39039B
63
7.1.2. Route Data
RODAI
ROU 2X This information will match the entry under
ROCAI.
TYPE TL45 TlU-45 trunk
VARC
Constant 0000000
Characteristics 3 Common Control
Tie Line
VARI
Constant 0000000
Characteristics 6 DTMF
Wink PTS
VARO
Constant 0000000
Characteristics 3 No B-answer supervision
DTMF
Wink PTS
7.1.3. Route Equipment
ROEQI
ROU 2X This information will match the entry under
ROCAI.
TRU
LIM-Trunk 1-1&&1-23
EQU
LIM 1
Magazine X This information must be added to the script file.
Board position XX This information must be added to the script file.
Board Circuit No. 0 First circuit on board.
INDDAT
Constant 0000000000
0 No block on excessive slip.
E CCS
B8ZS
ESF
No DMI