LIM CONFIGURATIONS FOR PUBLIC NETWORK CONNECTIONS LBI-39039B
59
ROEQI (Cont.)
EQU
LIM 1
Magazine X This information must be entered in the script file.
Board position XX This information must be entered in the script file.
Board Circuit No. 17
6.5.4. External Destination Codes
RODDI
DEST 0 Destination code
ROU 10
ADC
Trunk seizure 1 After minimum number length
Called Number type 0 Unknown
Number series 0 Variable length
Calling Number type public 0 Unknown
Calling Number type private 5 Unknown
Network 0 Not fiber optic or TNS
Release 0 First party release
Backward signaling 0 Send from first digit
Terminating and transit
seizure
0 Send terminate seizure signal
Off-hook Queuing threshold 0 No threshold
Expensive route warning tone 0 No ERWT
LCR accessibility 0 Accessible by all callers
Traveling Class Mark 0 Not sent
Return block 25 Limit on transit exchanges
PNR Number Translation Use 0 No Translation
SRT 1 Start digit for outgoing calls
External Destination Codes 1, 2, and 3 are identical to 0.