LBI-39039B LIM CONFIGURATIONS FOR PUBLIC NETWORK CONNECTIONS
52
6.4. NORTH AMERICA ANALOG CO TRUNK
With Line Clearing and Without B-Answer
Please refer to section 2.2 for a discussion of line clearing and B-answer supervision.
6.4.1. Route Class
ROCAI
ROU 3X This information must be added to the
script file. X will be 0-9. Make the first
Public Network route 30.
SEL
DID characteristics 0 No intercept
Incoming calls 1 Allowed
Outgoing trunk selection 1 Even load distribution
Terminal route characteristics
(outgoing)
0 Normal route
Alternate Route Selection
(incoming)
0 Permitted
Customer affiliation 00 No tenant group
Virtual network calls 1 No
Malicious call tracing 0 No
Default FRL category 0 Lowest level
Default CSI category 0 Normal extension
Receipt of FRL 0 No TCM received
TRM
Transmission Category 6 Analog CO or DID trunk
SERV
Call waiting and intrusion 3 CWT sent/received and intrudable
Automatic callback 1 Allowed
Type of trunks 0 CO or DID
Call metering 0 No
Paging 0 No
LCR threshold 3 Unrestricted
Release line trunk 0 No
CLI presentation 1 Not allowed
Request of CLI 0 Not allowed
Number conversion 0 No