DIRECT INBOUND RADIO CALLS IN A PBX NETWORK LBI-39039B
67
This entry is for direct 4-digit outbound radio dialing to extension range 1000-1999 on the other PBX.
LCDDI
TAB
Table
NLT Number Length Table
ENTRY 81
CONF Y
MIN 5
MAX
5
Similar entries will be made for extension series 2000-4999.
All “8+” dialing entries will have an “8” in front of the “8,” and the appropriate MIN and MAX.
All “9+” dialing entries will have an “8” in front of the “9,” and the appropriate MIN and MAX.
Direct dialing to MD110 extensions from the other PBX extensions is accomplished by simply dialing the MD110
extension number.
Direct dialing by radios to MD110 extensions is accomplished with this entry.
LCDDI
TAB
Table
NLT Number Length Table
ENTRY 85
TRC 1 One digit
CONF Y
MIN 5
MAX 5