LBI-39039B INDIRECT INBOUND RADIO CALLS IN A PBX NETWORK
72
Other PBX Extensions
The following three entries will provide for direct dialing to the other PBX extensions for numbers in the 1000-1999
range.
NACDS
NUM
Number
1 Possible first digit of outbound radio call or
MD110 extension call to other PBX extension
CDCAT
TCD Category allowed to dial
NUM
0&1 Extension and EDACS allowed
NANLS
EXL
External Number
1 First digit of other PBX extension
MIN
Minimum length
4
MAX
Maximum Length
4
RODDI
DEST 1 Destination code
ROU 20
ADC
Trunk seizure 0 Immediate
Number type 0 Unknown
Number series 0 Variable length
Network 0 Not fiber optic or TNS
Release 0 First party release
Backward signaling 0 Send from first digit
Terminating and transit
seizure
0 Send terminate seizure signal
Off-hook Queuing threshold 0 No threshold
Expensive route warning
tone
0 No ERWT
LCR accessibility 0 Accessible by all callers
Traveling Class Mark 0 Not sent
Return block 25 Limit on transit exchanges
SRT 1 Start digit for outgoing calls
The preceding three entries must be made for 2 and 6 (extensions 2000-2999 and 6000-6999).
LCR Code 9 tables must be generated per the customer's requirements.