CUTMASTER 40
OPERATION 0-5570
30
Postow
Release the trigger to stop the cutting arc. Gas continues to ow for approximately 10 seconds.
During post - ow, if the user quickly presses and releases the trigger, the gas will shut o. If the
user continues to hold the trigger and not release it, the pilot arc starts. The main arc will transfer
to the workpiece if the torch tip is within transfer distance.
Shutdown
Turn the ON / OFF switch to OFF, to the left as you face the unit from the rear. After a short delay
all Power Supply indicators and fan shut OFF. Unplug the input power cord or disconnect input
power. Power is removed from the system.
NOTE!
To maximize the longevity of the internal electronics, allow the power supply to continue running (without cutting) for
a few minutes before turning OFF. This will allow them to cool faster.