9 Halcyon Gold User Manual
Power
WARNING: Connect the fixture to a non-dimmable power source in order
to avoid damage to the fixture's internal power supply and other electrical
components. Using a dimmable power source can damage the fixture and
will void the warranty.
Electrical
100240 VAC at 50/60 Hz
Maximum power consumption: 684W
Input and Power Factor
The values listed below were measured with LEDs at full and all motors functioning.
VAC Amps Hz Watts VA PF
100 6.9 50 684 691 0.99
120 5.7 60 674 676 0.98
200 3.4 50 649 676 0.95
208 3.3 60 646 608 0.94
220 3.1 50 646 674 0.95
230 3.0 50 646 676 0.94
240 2.9 60 644 697 0.91
Fixtures per Circuit
Up to two fixtures are allowed per circuit via an ETC R20 or similar breaker module. Consult
the upstream breaker trip curves when using other equipment.
Connector Specifications
WARNING: Risk of Shock and Fire. Assemble a grounding-type attachment
plug with integral cord grip that is within the voltage and amperage rating
of this luminaire.
AVERTISSEMENT : Risque de choc et d'incendie. Assurez-vous d'utiliser
une prise de mise à la terre avec décharge de traction intége qui respecte
la tension et l'ampérage de ce luminaire.
A power input cable with powerCON
®
TRUE1
®
TOP input to bare ends is provided. The power
input cable is rated for maximum 20A/120VAC and 16A/240VAC. Install a suitable
connector to meet the installation requirements. See the following wire color code chart:
Wire Color Code (EU) Wire Color Code (US Standard) Connection type Terminal
Green/Yellow Green Earth/Ground
Blue White Neutral N
Brown Black Line (Live) L