EVBOX1 | Installation guide ver. 2.0 | Code 144BOX1E204
page 65 of 100
i1 0 1 - - - - 0 0 0 0 0 0 0 0
type of door micro switch input contact
0
=
normally open (active input with closed contact)
1
=
normally closed (active input with open contact)
i2 -1 120 min 30 30 30 30 30 30 30 30
delay in signalling of door micro switch input alarm (code
id”)
-1
=
the alarm will not be signalled
i3 -1 120 min 15 15 15 15 15 15 15 15
maximum duration of the effect caused by the activation
of the door micro switch input on the compressor and the
evaporator
i4 0 1 - - - - 0 0 0 0 0 0 0 0
storage of door micro switch input alarm (code “id”) (32)
1
=
YES