4 Commissioning
52/ 132 Enigma User Manual | © Eversys S.A.
4.2 Requirements prior to initial commissioning
A few preparations are necessary before your service engineer can set up your Enigma. The following
preparations must be carried out by a professionally qualified person.
Description OK Issue
Flat and clean surface
Clean environment
Space above min. 300 mm (11.8 in)
Stable table capable of bearing < 100 kg
E’6m < 150 kg
Table height 800 mm (31.5 in)
Countertop cutout, see “9.2.2” on page 103.
Separate electrical lines for each machine.
Electrical mains protected by RCD or RCCB
Water mains shutoff valve with a non-return valve (type EA
or according to local regulation)
Descaling cartridge or carbon filter as minimum
Water pressure 2.5 - 4 bars (32.3 - 58 psi) (250 - 400 KPa)
Pressure reducer (only if pressure is above 4.5 bars)
Flow rate above 200 L/h (Enigma, E’line)
Flow rate above 140 L/h (Cameo)
Water inlet 3/8" (AU and JA G 1/2)
The drain hose must be connected to a siphon (input min. Ø
56 mm (Ø 2.2 in).
Siphon input min. Ø 56 mm (Ø 2.2 in) according to EN
61770.
Machine installed with adequate back flow protection to
comply with applicable federal, state or local plumbing
codes.
Total hardness: 5 - 8° dGH (89-142 ppm)
Carbonate hardness: Max. 6° dKH (107 ppm)
pH value: ideal 7.0 - 7.2
Chlorine (Cl) max. 0.1 mg/l