EasyManua.ls Logo

Evinrude E-TEC E40DPLSCB - Page 13

Evinrude E-TEC E40DPLSCB
369 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INTRODUCTION
SERVICE SPECIFICATIONS
11
40 – 65 HP E-TEC Models
ELECTRICAL
Minimum Battery
Requirements
640 CCA (800 MCA) or 800 CCA (1000 MCA) below 32° F (0° C)
Alternator 25-Amp fully regulated
Tachometer Setting 6 pulse (12 pole)
Engine Fuse P/N 967545 – 10 A
COOLING
Thermostat 143°F (62°C)
Maximum Temperature 212°F (100°C)
Water pressure 11 psi minimum @ 5000 RPM
IGNITION
Type Capacitor Discharge
Firing Order 1-2
Ignition Timing EMM Controlled
RPM Limit in Gear 6250
RPM Limit in Neutral 1800
Crankshaft Position Sensor Air
Gap
Fixed
Spark Plug
Refer to Emission Control Information Label
Champion
QC10WEP @ 0.028 ± .003 in. (0.71 mm)
GEARCASE
Gear Ratio 12:32 (.375)
Lubricant
HPF XR Gearcase Lube
HPF Pro in high performance or commercial applications
Capacity 22 fl. oz. (650 ml)
Shift Rod Height 20 in. (L) Models: 21.38 (543 mm) ± one-half turn
Shift Cable Stroke 1.125 to 1.330 in. (28.6 to 33.8 mm) measured between NEUTRAL and FORWARD
POWER TRIM/TILT
Lubrication Evinrude/Johnson Biodegradable TNT Fluid
Fluid Capacity 15.2 fl. oz. (450 ml)
Trim Range 0° to 15°
Tilt Range 16° to 65°

Table of Contents

Related product manuals