185
OILING SYSTEM
OILING SYSTEM TESTS
9
Oil Injection Fittings Flow Test
Make sure the oil injection fittings of the cylinder
and crankcase assembly allow fluid to move.
Remove oil distribution hose from oil distribution
manifold.
Use a Syringe, P/N 346936, filled with isopropyl
alcohol to force fluid through hose and fitting.
LOW OIL Sending Unit Test
Remove the oil from the oil tank.
Turn the key switch ON. The dash mounted
Engine Monitor system should show a LOW OIL
warning.
Once the warning has been confirmed, refill the oil
tank and start the outboard. The LOW OIL warn-
ing should stop after the oil pump cycles 3 times.
1. Syringe 002376