EasyManua.ls Logo

Evinrude E-TEC E40DPLSCB - Packard Connectors

Evinrude E-TEC E40DPLSCB
369 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
151
ELECTRICAL AND IGNITION
CONNECTOR SERVICING
7
POWER TIMER
SERIES
The J2 connector of the EMM is a AMP Power
Timer Series connector.
Disconnect
Use a screw driver to open latch. Pull connector
from plug.
Connect
Push connector until seated in plug. Close latch
completely.
Terminal Removal
Use Terminal Release Tool, P/N 351413, to
release BOTH locking mechanisms of connector.
Pull terminal from housing.
Terminal Installation
Align terminal with connector housing and push
terminal with seal into connector housing until
seated.
Packard
Connectors
IMPORTANT: Always use the appropriate meter
test probes and adapters when testing compo-
nents fitted with these terminals.
Disconnect
Lift latch(s). Remove connector.
Connect
Confirm the seal is in place. Push connector onto
housing until latched.
1. J2 connector
2. Latch (closed)
002120
1. Locking mechanism(s) 002455
1. Terminal release tool 002313
1
2
1
1
1. Latch
2. Terminal with seal
002456
DSC02124
1
2

Table of Contents