EasyManuals Logo

Evoqua IONPURE IP-MXM30 User Manual

Evoqua IONPURE IP-MXM30
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
IONPURE
®
MX CEDI Modules
Page 28 of 32 IP-MAN-MX-Rev E
Have DC volts
increased?
Reduce flow
or reduce feed
conductivity equivalent
See separate
troubleshooting
chart for DC volts
Yes
No
Go to Next Flowchart
Product flow
increased?
Yes
Troubleshooting Flow Chart - Low CEDI Product Water Quality
Page 2 of 3
Continued from previous
flowchart
Increase
DC amperage
Check IP-Pro:
is desired quality
possible?
Yes
No
No
Is reject out psi
> product out psi?
No
Adjust product out to
2-5 psi > reject out
Yes
Go to chart for
DC Volts