Page #29 background image
IONPURE
®
MX CEDI Modules
Page 29 of 32 IP-MAN-MX-Rev E
Did cleaning
restore flow?
Clean CEDI with
NaCl/NaOH and
Na
2
CO
3
/H
2
O
2
Resin oxidized
(affects flow & quality)
or fouled
(affects quality)
Has
product flow
decreased?
Troubleshooting Flow Chart - Low CEDI Product Water Quality
Page 3 of 3
Continued from
Previous Flowchart
No
Yes
Contact Ionpure Technical
Support
www.ionpure.com
Did cleaning
restore quality?
No
Removed particulates
and/or biofilm:
review process
design & operation
Yes
Also removed
organics from resin:
review process
design & operation
Yes
No
Check feed water Cl
2
Check sanitization
procedure