EX-2001 NC RACER ZSME300000091
17
EXCELL PRECISION CO., LTD.
Recall Linearity correction point
Set the calibration switch to ON position.
Press key
Choose linearity calibration
Press key
Press key
Press key
After finishing the first linearity calibration,
choose to continue or exit the linearity mode
by pressing .
The weight value is displayed.
Increase the number of
the flashing digit by one
Decrease the number
of the flashing digit by
one
Shift the flashing digit
one space to left
Shift the flashing digit
one space to right
Save the settings
Exit the settings
C A L
ENTER
GROSS
NET
STANDBY
OPERAE
STANDBY
OPERAE
ZERO
+
TARE
Five point linearity calibration.
Choosing from 1P ~ 5P by
pressing key.
No linearity
calibration value at this point
Linearity
calibration value at this point
TARE
PRINT
ZERO
+
GROSS
NET
ENTER
STANDBY
OPERAE