EasyManua.ls Logo

Excell NC RACER EX-2001 - Status Information; Units and Terminators; Command Mode Interface

Default Icon
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EX-2001 NC RACER ZSME300000091
25
EXCELL PRECISION CO., LTD.
Status
Stable: display “blank” Unstable: display “M” Over load: display “O”
Units
Kg, g, t, lb or “blank”
Terminators
CR, LF is the data finish code.
2
Command mode
COMMAND FUNCTION
READ, RW Reads weight
ZERO, MZ Back to zero
TARE, MT Tare
NTGS Switches gross / net weight
MG Displays gross weight
MN Displays net weight
CT Clears tare
n The command string must be terminated with CR ( 0DH ) , LF ( 0AH ).
o If a wrong command is received, the indicator will reply “E” + “ error command ”.
p If the command mode has been selected “with address”, (FUNC. 61 = 4)
then every command must be preceded with an indicator address in the format:-
“ @ address ”
Example: To read the weight value form indicator addressed as 01 (“01” selected in
FUNC. 67) The complete command is @01RW<CR><LF>