3. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg).
FIGURE 14 Attaching the rear brackets to the device
1. Screws, 8-32 x 5/16-in., panhead Phillips
Mid-mounting
Observe the following notes when using this procedure:
The device must be turned
o and disconnected from the fabric during this procedure.
The illustrations in this document show a 1U device, but the instructions are the same for a 2U device.
The illustrations in the rack installation procedures are for reference only and may not show the actual device.
Complete the following tasks to install the device in a rack:
1. Attaching the front brackets to the device on page 35
2. Attaching the front brackets to the rack on page 36
3. Attaching the rear brackets to the rack on page 37
4. Attaching the rear brackets to the device on page 38
Attaching the front brackets to the device
Complete the following steps to attach the front brackets to the device.
1. Position the right front bracket with the at side against the right side of the device, as shown in Figure 15.
Installing the Universal Two-Post Rack Kit (XEN-R000294)
ExtremeSwitching SLX 9540 Hardware Installation Guide
9036360-00 Rev AB 35