Perform the following steps to establish an Ethernet connection to the device.
1. Remove the shipping plug from the Ethernet port on the active management module.
The active management module has the LED labeled ACTIVE on the front panel illuminated in blue.
2. Insert one end of an Ethernet cable into the Management Ethernet port.
FIGURE 32 Port-side view of the SLX 9540 Switch
1. 10/100/1000Base-T RJ-45 management Ethernet port
2. SFP ports 1-48
3. QSFP28 ports 49-54
4. RS-232 port
5. USB port
3. Connect the other end to 1 G, 100 MbE, or 10 MbE Ethernet LAN.
4. Complete any additional device conguration procedures for the device using one of the following steps:
• Log in to the device using a serial console connection and admin login.
• Log in to the device through a Telnet or SSH session using the chassis management IP address and admin login.
Customizing the chassis and host names
To
congure a chassis and host name, complete the following task.
The chassis and host names can be up to 30 characters long; can include letters, numbers, hyphens, and underscore characters; and
must begin with a letter.
Extreme recommends that you customize the chassis name for each platform because some of the system logs refer to the platform by
its chassis name.
1. Log in to the device using one of the following methods:
• A serial console connection to the active management module. The active management module has the LED labeled
ACTIVE on the front panel illuminated in blue.
• A Telnet session using the chassis management IP address.
2. Log in to the device using admin as your login name. If you have not changed the default password, use password.
3. Change the chassis name by completing the following steps.
a) Enter congure terminal to enter global conguration mode.
b) Enter switch-attributes chassis-name chassis-name, where chassis-name is the new chassis name.
c) Enter exit to return to privileged EXEC mode.
d) To verify the new chassis name, enter the show chassis command.
Customizing the chassis and host names
ExtremeSwitching SLX 9540 Hardware Installation Guide
58 9036360-00 Rev AB