5. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg).
FIGURE 21 Attaching the bracket extensions to the device
1. Bracket extension 2. Screws, 8-32 x 5/16-in., athead Phillips
Installing the device in the rack
Complete the following steps to install the device in the rack.
1. Position the device in the rack, as shown in Figure 22, providing temporary support under the device until the rail kit is secured
to the rack.
2. Attach the right front bracket to the right front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use
the upper and lower holes in the bracket.
3. Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the
upper and lower holes in the bracket.
Installing the Universal Four-Post Rack Kit (XEN-R000296)
ExtremeSwitching SLX 9540 Hardware Installation Guide
44 9036360-00 Rev AB