IN1804 Seamless Scaling Switchers • SIS Configuration and Control 55
X3$
= Verbose mode
0 = None (default for LAN connection)
1 = Verbose mode (default for RS-232 and USB
connection)
2 = Tagged responses to queries
3 = Verbose mode and tagged responses
NOTES:
• In verbose response mode, the IN1804
returns unsolicited responses for value
and setting changes that may result from
a signal change, or a setting adjustment
made via another interface.
Example: The IN1804 can send out a
notice of a change in some setting without
receiving a query via a PC or a control
system. That change could have been a
result of an internal process or a selection
made via the PCS program. This is a
verbose (wordy) relationship between the
controller and a connected device.
• If tagged responses are enabled, all
“view” commands return the command
string plus the data, the same as in
responses for setting a value. For example:
Command:
X!
*\
Response: Vtyp
X!
*
X#]
or
X#]
(untagged)
X3%
= Model name
IN1804, IN1804 DI, IN1804 DO, or IN1804 DI-DO
X3^
= Part number
IN1804 (standard) — 60-1699-01 or 60-1699-11
IN1804 DI — 60-1699-02 or 60-1699-12
IN1804 DO — 60-1699-03 or 60-1699-13
IN1804 DI/DO — 60-1699-14
X3(
= Aspect ratio setting
1 = Fill — Each input rate fills the entire output
raster (default).
2 = Follow — Each input rate is displayed with its
native aspect ratio.
X4)
= Screen saver mode
1 = Black screen (default)
2 = Blue screen with OSD text
3 = User image on black screen
X4@
= Video output mute
0 = Unmute
1 = Mute video to black screen
2 = Mute video and sync
X4#
= User logo number
1 through 16. The response is three digits padded with
leading zeros.
101 = No signal, screen saver user logo
201 = User HDCP logo
X4$
= HDCP status
0 = No sink or source device detected
1 = Sink or source detected but no HDCP present
2 = Sink or source detected with HDCP