IN1804 Seamless Scaling Switchers • SIS Configuration and Control 62
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Input Configuration (continued)
Auto-input Switch Mode
Set the auto-input switch
mode
EX3)
AUSW
}
Ausw
X3)]
Set the auto-input switch mode to
X3)
.
View auto-input switch
mode
E
AUSW
} X3)]
View current auto-input switch mode
X3)
.
Set user priority order for
auto-input switch mode 1
E
P
X3!
X3!
X3!
X3!
AUSW
}
AuswP
X3!
X3!
X3!
X3!]
Set the input priority switching order,
highest priority (first) to lowest (last).
NOTE: The Set Priority command returns an E13 error code unless the correct number of
X3!
variables are entered.
View mode 1 priority order
E
P AUSW
} X3!
X3!
X3!
X3!]
View the order in which the inputs will
be selected in auto-input switch mode
1 (highest to lowest priority).
Set timeout
E
T
X3@
AUSW
}
AuswT
X3@]
Set the amount of time without video to
switch to the previous input.
View timeout
E
TAUSW
}
X3@]
View the auto-input switch timeout
duration in seconds.
KEY:
X3)
= Auto-input switch mode
0 =
Disabled — Manual switching (default)
1 =
User-defined priority mode
The switcher selects the
input to which the user assigns priority. If no priority is
assigned, the switcher selects the active input with the
lowest number.
2 =
Last connected mode
The switcher selects the
most recently applied input, and retains a history of the
order in which active inputs are connected to the unit. If an
active input is removed, the switcher switches to the most
recently prioritized input.
X3!
= Input number for setting user priority
Arrange input numbers in user priority order.
1 = input 1, 2 = input 2, 3 = input 3, 4 = input 4
X3@
= Auto-input switch timeout
Amount of time without video that elapses before switching to
the input with the next priority.
1 through 500 (in 1-second increments, default = 3 seconds)
0 =
Immediately switch to the input with the next priority if the
current input is removed.