IN1804 Seamless Scaling Switchers • SIS Configuration and Control 67
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Output Configuration (continued)
Screen Saver
Set mode
E
M1*
X4)
SSAV
}
SsavM1*
X4)]
Set the screen saver mode for the
output to
X4)
.
View mode
E
M1 SSAV
} X4)]
View the screen saver mode
X4)
for the
output. Default = 1 (black).
Set screen saver duration
before output sync timeout
E
T1*
X2*
SSAV
}
Ssav T1*
X2*]
Set the screen saver timeout duration to
X2*
seconds. Default = 501 (never).
View screen saver duration
before output sync timeout
E
T1SSAV
}
X2*]
View screen saver timeout duration
X2*
.
View screen saver status
E
S1SSAV
} X6#]
Verbose modes 2 and 3:
Ssav S 1*
X6#
]
View screen saver status
X6#
.
OSD Menu Duration
Set OSD duration
EX2*
MDUR
}
Mdur
X2*]
Set the OSD menu duration to
X2*
.
View OSD duration
E
MDUR
} X2*]
View the OSD menu duration.
KEY:
X2*
= Output sync or OSD menu timeout
Number of seconds before output sync or the OSD menu times out.
1 through 500 seconds, in 1-second increments
0 = Output sync is instantly disabled with no active video from the
selected input (not allowed for MDUR command).
60 = Default for the MDUR command.
501 = Output sync never times out (default for SSAV command).
X4)
= Screen saver mode
1 = Black screen (default)
2 = Blue screen with OSD text
3 = User image on black screen
X6#
= Screen saver status
0 = Active input detected, timer not running
1 = No active input, timer running, output sync still active
2 = No active input, timer expired, output sync disabled
Logos
Logo Assignment
Select image file
E
A
X4#
,lename LOGO
}
LogoA
X4#
,lename
]
Assign logo filename to logo slot
X4#
.
NOTES:
The lename must consist of a full path name if the file is not in the /Graphics directory.
The file name must include the extension (.png, .bmp, .jpg, .gif, .tif, and so on).
If the file is not in the /Graphics directory, include a / before the filename to indicate that it is in the root directory.
Example: /Logo123.bmp.
View selected logo file
E
A
X4#
LOGO
}
lename
]
View the logo filename assigned to logo
X4#
.
KEY:
X4#
= User logo number
1 through 16. The response is three digits padded with leading zeros.
101 = No signal, screen saver user logo or image is displayed.
201 = User HDCP logo displayed

Table of Contents