IN1804 Seamless Scaling Switchers • SIS Configuration and Control 75
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Advanced Configuration (continued)
HDCP Output Mode
Set HDCP mode
E
S
X@
*
X4^
HDCP
}
HdcpS
X@
*
X4^]
Set the HDCP output mode
X4^
for
output
X@
.
View HDCP mode
E
S
X@
HDCP
} X4^]
View the HDCP output mode for output
X@
.
HDCP Notification
Set HDCP notification
E
N1*
X4&
HDCP
}
HdcpN1*
X4&]
Set the HDCP notification to
X4&
.
View HDCP notification
E
N 1 HDCP
} X4&]
View the HDCP notification selection.
Video Signal Presence
View signal presence
E
0LS
} X6!
*
X6!
*
X6!
*
X6!]
Verbose modes 2 and 3:
IN00•
X6!
*
X6!
*
X6!
*
X6!]
View video signal status
X6!
for inputs 1
through 4.
Front Panel Lock (Executive Mode)
Enable lock (mode 1)
1X
Exe1
]
Lock all front panel controls.
Enable lock (mode 2)
2X
Exe2
]
Lock all front panel functions except
input switching.
Disable lock mode
0X
Exe0
]
Unlock all front panel controls. All front
panel adjustments can be made.
View lock mode status
X
X2(]
View current lock mode status
X2(
.
KEY:
X@
= Output
1 =TP Output 1A (IN1804 DO and DI/DO)
HDMI output 1A (IN1804 and IN1804 DI)
2 = HDMI output 1B
X2(
= Front panel lock (executive mode)
0 = Off or disabled (front panel controls fully accessible) (default).
1 = Mode 1 — Complete front panel lockout
2 = Mode 2 — Input switching only
X4^
= HDCP output mode
0 = Off — Disable all HDCP authentication and encryption attempts.
1 = Follow input (default).
2 = Always encrypt.
3 = Follow input (with continuous authentication trials).
4 = Always encrypt (with continuous authentication trials).
X4&
= HDCP notification mode
0 = Black screen — Notification disabled (mute output)
1 = Green screen with OSD bug (orbiting message) (default)
2 = User image with black screen background
NOTE: A green screen with HDCP Content orbiting text or an HDCP user logo is visible only if a single non-
compliant display is attached, or if both attached displays are non-HDCP compliant. If the IN1804 is connected to
one compliant and one non-compliant display at the same time, only a green or black screen with no text or logo
appears on the non-compliant display.
X6!
= Video signal status
0 = Video, TMDS, or DP signal not detected
1 = Video, TMDS, or DP signal detected